Explosion Proof Solution Complies with Japanese explosion-proof test Exia IIB T4 NSD’S explosion proof solution is consist with the contoller and sensor and explosion safety barrier in btween. Extension sensor cable up to 200m

System Configuration

Fig:Explosion Proof Solution System Configuration Absocoder sensor sets in the hazardous area Controller and safty barrier set in the safe area

List of products

Absocoder Sensor Extension sensor cable Safety barrier Converter connection cable Controller model
Single-turn type VRE-EXIP028SAB

Single-turn type VRE-EXIP028SAB

4P-EP-5152-(Max.100m) (Robotic cable)

BA-3PEXI-G

Safety barrier

4P-S-0140-(Max.5m) NCV-20NBNVP-EXI Converter Output=Binary code
NCV-20NGNVP-EXI Converter Output=Gray code
4P-EP-S-6465-(Max.200m) (Standard cable) VS-6E-EXI VARICAM Output=Switch
Single-turn type VRE-EXIP062□□B

Single-turn type VRE-EXIP062□□B

4P-EP-5152-(Max.100m) (Robotic cable) VS-1AN-1-EXI-V1PG VARIANALG Output=Analog voltage
4P-EP-S-6465-(Max.200m) (Standard cable) NPG-10NAAVP-EXI ABSO PULPUL Output=A/B/Z phase pilse
Single-turn type VRE-EXI10TP058MSB

Single-turn type VRE-EXI10TP058MSB

4P-EP-5152-(Max.100m) (Robotic cable)

BA-3PEXI-VT

Safety barrier

4P-S-0140-(Max.5m) NPG-10NAAVT-EXI ABSO PULPUL Output=A/B phase pilse
4P-EP-S-6465-(Max.200m) (Standard cable)
Multi-turn type MRE-EXI32SP061□□B

Multi-turn type MRE-EXI32SP061□□B

4P-EP-5152-(Max.60m) (Robotic cable)

BA-4PEXI-MR

Safety barrier

4P-S-0140-(Max.5m) NCV-20NBNMR-EXI Converter Output=Binary code
NCV-20NGNMR-EXI Converter Output=Gray code
4P-EP-S-6465-(Max.100m) (Standard cable) VM-2CC-EXI (CC-Link) Network Converter Output=Binary code
Multi-turn type MRE-EXIG□SP061F□B

Multi-turn type MRE-EXIG□SP061F□B

4P-EP-5152-(Max.100m) (Robotic cable) VS-10FD-1-EXI VARILIMIT Output=Switch,Current position display
4P-EP-S-6465-(Max.200m) (Standard cable) VS-212DN-EXI (DeviceNet対応) VARILIMIT(2 axes) Output=Switch,Positioning
Linear type (Submicron Absocoder) VLS-EXI1.64SS6AB

Linear type (Submicron Absocoder) VLS-EXI1.64SS6AB

 

3S-EP-5152-(Max.100m) (Robotic cable)

BA-3SEXI-P

Safety barrier

3S-S-0140- (Max.5m)-S045 VL-2-S1-EXI Converter Output=Binary code
Linear type VLS-EXI8PSM□□□

Linear type VLS-EXI8PSM□□□

4P-EP-5152-(Max.60m) (Robotic cable)

BA-3PEXI-P

Safety barrier

4P-S-0140-(Max.5m) NCV-20NBNLP-EXI Converter Output=Binary code
NCV-20NGNLP-EXI Converter Output=Gray code
4P-EP-S-6465-(Max.120m) (Standard cable) VS-10BHC-D-EXI-LP VARILIMIT Output=Switch,Current position display
Cylinder type IRS-EXI51.2P□□□□AB□

Cylinder type IRS-EXI51.2P□□□□AB□

4P-EP-5152-(Max.100m) (Robotic cable)

BA-3PEXI-C

Safety barrier

4P-S-0140-(Max.5m) NCV-30NBNLC-EXI Converter Output=Binary code
4P-EP-S-6465-(Max.200m) (Standard cable)
ABSOCODER Built-In Sensing Products (Wire Runner) WR-EXI10B1

ABSOCODER Built-In Sensing Products (Wire Runner) WR-EXI10B1

4P-EP-5152-(Max.60m) (Robotic cable)

BA-4PEXI-MR

Safety barrier

4P-S-0140-(Max.5m) NCV-20NBNMR-EXI Converter Output=Binary code
NCV-20NGNMR-EXI Converter Output=Gray code
VM-2CC-EXI(CC-Link) Network Converter Output=Binary code
4P-EP-S-6465-(Max.100m) (Standard cable)
VS-10FD-1-EXI VARILIMIT Output=Switch,Current position display
VS-212DN-EXI (DeviceNet) VARILIMIT(2 axes) Output=Switch,Positioning

Ex ia IIB T4

①Indicates the product is certified the international standard
②Type of protection
  • ia: Intrinsic safety
③Grouping of gas/vapour
  • II B
④Grouping of gas/vapour
  • II B
⑤Temperature class
  • T4: The maximum surface temperature is up to 135℃
Use in Overseas
This product passed the Japanese explosion-proof test only. Get the explosion-proof certification in each country if it is used under the explosion-proof environement in countries except Japan.

.